Origin |
China |
Output Type |
Single |
AC input range selectable by switch Protections: Short circuit/ Overload Cooling by free air convection 100% full load burn-in test Low cost, hogh reliability 1 year warranty
AC input voltage range ......... 85~132VAC / 180~264VAC selectable by switch AC inrush current .................. Cold start, 30A at 115VAC, 60A at 230VAC DC adjustment range ............ iexcl;10% rated output voltage Overload protection ............. 105%~150% shut off, AC recycle to re-start (S-100-7.5: 150%~200%) Setup, rise, hold up time .. 200ms, 80ms, 20ms at full load and 230VAC Withstand voltage ................. I/P-O/P:1.5KVAC, I/P-FG:1.5KVAC, 1 minute Working temperature ............ -10~60OC (refer to output derating curve) Safety standards ................... Design refer to UL1012 EMC standards ..................... Design refer to FCC part 15 J Connection ............................ 7P / 9.5mm pitch terminal block Packing .................................. 0.62kg ; 20pcs / 13.6kg / 0.8CUFT
|